Only available in Belgium
Pump customization is now easier with the new OEM modules. Integrate these modules into your systems or work with our
engineering staff to design different syringe mechanisms or controllers. We offer the technology and engineering expertise to
meet your demanding applications. It is possible to customize modules to meet your application requirements. With our technical
expertise in syringe pump design, we can meet even the most demanding applications at an affordable price. OEM pumps
can be modified with different mechanisms and configurations. The basic models are shown below:
Microliter & Milliliter Syringe Pump Modules are Highly Precise:
Based on the Legato® 100 series syringe pump design, the NEW Legato® 950 is ideal for applications interfacing to a computer.
Accommodates syringes 0.5 μl to 60 ml. User definable flow rates with selectable target volume or time values to control
the total infusion volume.
The NEW Legato® 380 emulsifying system is based on the Legato® Series of syringe pumps. It utilizes a modified Legato®
210P and Legato® 270P. All the standard features of the Legato® products are still available, but a custom emulsification
program has been added to the software. This program is only available with the Legato® 380 system. The Legato® 210P and
Legato 270P can also be used as stand alone syringe pumps. The emulsifiying system mimics the same action as in manually
pushing fluid back and forth between syringes, but does it automatically. You select the volume and the emulsifying rate. The
pumps will automatically move the fluid back and forth between the syringes for a user determined time or number of cycles.
• Eliminate fatigue associated with manual emulsification
• Automatically move solutions between two syringes
• Multiple functionality – use as independent syringe pump units
• Selectable emulsifying rates
• Selectable volumes
• Adjustable duration – Enter the number of cycles or the total time
• Adjustable force makes it ideal for viscous fluids – up to 75 lbs (34 kg) of linear force
• Flexible syringe sizes and types
Dual Rate Pump
This unique pump is really two pumps in one. Each side of the Gemini 88 has its own syringe rack, motor and leadscrew. The
pump can infuse simultaneously at different rates, or infuse with one syringe and withdraw with the other. When combined
with a valve box it provides continuous delivery.
900 | 910 | Legato 950 | Gemini 88 | Legato 380 | |
Model | Microliter OEM | Milliliter OEM | Legato OEM | Independant Rate Control | Emilsifier |
Mode | Infuse/Withdraw | Infuse/Withdraw | Infuse/Withdraw | Infuse/Withdraw/Continous | Infuse/Withdraw/Push-Pull Emulsify |
Number of Syrings | One | One | One | Two Independent | Fout |
Syringe Size | 0,5µl to 1 ml | 0,5µl to 60 ml | 0,5µl to 60 ml | 0,5µl to 140 ml | 0,5µl to 140 ml |
User Interface | Computer | Computer | Computer | Keypad with Numerics | Touch screen |
Display | N/A | N/A | N/A | Backlit LCD | 4,3" QVGA |
Accuracy | +/- ≤ 0,35% | +/- ≤ 0,35% | +/- ≤ 0,5% | +/- ≤ 0,5% | +/- ≤ 0,35% |
Repeatability | +/- 0,1% | +/- 0,1% | +/- 0,05% | +/- 0,1% | +/- 0,05% |
Linear Force (Max) | 7lbs Peak Min Adjustable | 25 lbs Peak Min Adjustable | 13,6 kg @ 100% Force selection | 28,5 kg | 34 kg @ 100% Force selection |
Minimum Flowrate 10µl Syringe | 216 pl/hr | 216 pl/hr | 28,26 pl/min | 6600 pl/hr | / |
Maximum Flowrate 10 ml Syringe | 1330 µ/min (1ml-syringe) | 13,286 ml/min | 25,99 ml/min | 15,733 ml/min | 31,190 ml/min |
Maximum Flowrate 60 ml Syringe | / | 44,283 ml/min | 88,28 ml/min | 53,346 ml/min | 105 ml/min |
Maximum Flowrate 140 ml Syringe | / | / | / | 106,6 ml/min | 220,97 ml/min |
Drive Motor | 0,9° stepper motor | 0,9° stepper motor | 0,9° stepper motor | 0,9° stepper motor | 1,8° stepper motor |
Microprocesser Motor Drive Control | 1/4 and 1/16 Microstepping | 1/4 and 1/16 Microstepping | 1/16 Microstepping | 1/2 and 1/4 Microstepping | 1/16 Microstepping |
#microsteps/one revolution of lead screw | / | / | 15360 | 1600 steps ar 1/2 stepping or 3200 steps at 1/4 stepping | 6400 |
Advance per microstep | / | / | / | 0,33 µm/µstep | 0,1656 µm/µstep |
Minimum Step Rate | 3,8 s/µstep | 3,8 s/µstep | 27,5 s/µstep | 27,3 s/µstep | 27,5 s/µstep |
Maximum Step Rate | 250 µs/µstep | 250 µs/µstep | 26 µs/µstep | 416,7 µs/µstep | 26 µs/µstep |
Pusher Travel Rate | |||||
Minimum | 1,3 µm/min | 1,3 µm/min | 0,15 µm/min | 0,726699 µm/min | 0,3 µm/min |
Maximum | 83,4 mm/min | 83,4 mm/min | 159 mm/min | 95,25 mm/min | 190,80 mm/min |
Multi-step programming | No | No | No | No | Custom Emulsifying Program |
Constant rate | / | / | / | / | Yes |
Ramp | / | / | / | / | Yes |
Pulsed | / | / | / | / | Yes |
Stepped | / | / | / | / | Yes |
Program Export/Import | No | No | No | No | Yes |
Pusher Block stall Detection | No | Yes | Yes | Yes | Yes |
Computer Interface | RS-232 | RS-232 | USB | RS-232 | USB/RS-232 |
TTL | No | No | Yes | Yes | Yes |
Networking | Yes | Yes | RS-485 | Yes | RS-485 |
Real time Clock | No | No | No | No | Yes |
External triggers | No | No | One | No | Two |
Analog Output | No | No | No | No | Yes (optional) |
Footswithc Interface | Yes | Yes | Yes | No | Yes |
Maintenance Reminder | No | No | Yes | No | Yes |
Calibration Reminder | No | No | Yes | No | Yes |
Password Lock | No | No | Yes | No | Yes |
Audible Alarm Indication | No | No | End of run (optional) | End of run (optional) | End of run, Near end of run, Stall detection, Power-up, Keypad-clicks, Calibration reminder |
Display Rotation | N/A | N/A | No | No | Automatic |
Multisyringe Rack Accesories | No | No | No | No | No |
Run LED | No | No | No | No | Yes |
Weight | 0,8 kg | 1,23 kg | 3,62 kg | 9,8 kg | 9,8 kg each |
Dimensions (cm) HxWxL | 18,4*19,2*11,4 | 23*15,25*13 | 15,25*10,16*24,13 | 31,75*28,57*15,25 | Dependet on syringe size |
Certification | / | / | Yes | / | / |
CE,ETL,UL, CSA, CB, Scheme | CE | CE | Yes | CE | Yes |
EN61010, EN61326 | CE | CE | Yes | CE | Yes |